35 kV olejový transformátor energie
20000kva 35KV
20000kva 35KV
3150KVA 35KV
| Menovitá kapacita (KVA) | Kombinácia napätia | Pripojiť sa k štítku skupiny | Strata bez zaťaženia (W) | Strata zaťaženia (W) | Skratová impedancia (%) | Prúd naprázdno (%) | ||
| Vysoké napätie (KV) | Tapoff % | Nízky tlak (KV) | ||||||
| S13-50/35 | 38.5 35 | ±5 ±2x2,5 | 0.4 | Dyn11 Yyn0 | 128 | 1200/1140 | 6.5 | 1.30 |
| S13-100/35 | 184 | 2010/1910 | 1.10 | |||||
| S13-125/35 | 216 | 2370/2260 | 1.10 | |||||
| S13-160/35 | 224 | 2820/2680 | 1.00 | |||||
| S13-200/35 | 272 | 3320/3160 | 1.00 | |||||
| S13-250/35 | 320 | 3950/3760 | 0.95 | |||||
| S13-315/35 | 384 | 4750/4530 | 0.95 | |||||
| S13-400/35 | 464 | 5740/5470 | 0.85 | |||||
| S13-500/35 | 544 | 6910/6580 | 0.85 | |||||
| S13-630/35 | 664 | 7860 | 0.65 | |||||
| S13-800/35 | 784 | 9400 | 0.65 | |||||
| S13-1000/35 | 920 | 11500 | 0.65 | |||||
| S13-1250/35 | 1120 | 13900 | 0.60 | |||||
| S13-1600/35 | 1350 | 16600 | 0.60 | |||||
| S13-2000/35 | 1590 | 19700 | 0.55 | |||||
| S13-2500/35 | 1890 | 23200 | 0.55 | |||||
| Menovitá kapacita (KVA) | Pripojiť sa k štítku skupiny | Kombinácia napätia | Prúd naprázdno % | Strata bez zaťaženia W | Strata zaťaženia (120 ℃) W | Impedančné napätie % | ||
| Vysoké napätie (KV) | Rozsah vysokotlakového kohútika % | Nízky tlak (KV) | ||||||
| SCB10-315/35 | Yyn0 or Dyn11 | 35 or 38.5 | ±5 alebo ±2 x 2,5 | 0.4 3.15 6 6.3 10 10.5 11 | 2 | 1160 | 4170 | 6 7 8 9 |
| SCB10-400/35 | 2 | 1360 | 5360 | |||||
| SCBI10-500/35 | 2 | 1600 | 6590 | |||||
| SCB10-630/35 | 1.8 | 1840 | 7680 | |||||
| SCB10-800/35 | 1.9 | 2220 | 9350 | |||||
| SC810-1000/35 | 1.9 | 2640 | 10880 | |||||
| SCB10-1250/35 | 1.7 | 3090 | 12840 | |||||
| SCB10-1600/35 | 1.7 | 3650 | 15390 | |||||
| SCB10-2000/35 | 1.5 | 4200 | 18110 | |||||
| SCB10-2500/35 | 7.5 | 4800 | 21680 | |||||
| SCB10-3150/35 | 1.3 | 5000 | 24400 | |||||
| SC810-4000/35 | 1.3 | 6950 | 29330 | |||||
| SCB10-5000/35 | 1.1 | 8320 | 34770 | |||||
| SCB10-6300/35 | 1.1 | 9840 | 40630 | |||||
| SCB10-8000/35 | Yd11 or Ynd11 | 1 | 11200 | 45050 | ||||
| SCB10-10000/35 | 1 | 12800 | 51200 | 7 | ||||
| SC810-12500/35 | 0.9 | 16150 | 55300 | |||||
| SCB10-16000/35 | 0.8 | 19560 | 59800 | |||||
1. Proces návrhu rozvodne: fázový prístup 110 kV rozvodne trvalo 16 mesiacov od konceptu po napájanie, preto...
ČÍTAJ VIACVýkonový transformátor 40 MVA vypne diferenciálnu ochranu po poruche napájača. Olejové testy čisté. Odpor vinutia ...
ČÍTAJ VIACČo je polovodičový transformátor (SST)? V roku 2022 jeden európsky pilotný projekt vymenil konvenčný distrib...
ČÍTAJ VIACKríza nedostatku transformátorov: Prečo sú nové rastliny kritické Viac ako 80 % veľkých výkonových transform...
ČÍTAJ VIAC